Table. 3.

Table. 3.

Difference in SE after adjusting target SE

Difference of SE * Target SE (eyes) Adjusted target SE (eyes)
>2.0 D 6 (10.7) 0
1.5-2.0 D 7 (12.5) 2 (3.6)
1.0-1.5 D 12 (21.4) 10 (17.9)
0.5-1.0 D 13 (23.2) 19 (33.9)
<0.5 D 18 (32.1) 25 (44.6)
Total 56 (100) 56 (100)

Values are presented as number (%).

SE = spherical equivalent; D = diopters.

* Difference between target SE and postoperative SE; Target SE -.84 D.

J Retin 2020;5:143-8 https://doi.org/10.21561/jor.2020.5.2.143