eISSN 2508-3589
pISSN 2508-1926

Table. 2.

Table. 2.

Multiple regression analysis of factors affecting extent of inner retinal dimple

Independent variable Beta standard error p-value VIF
M-score* 0.349 0.068 < 0.001 1.001
Dye* 0.069 0.029 0.02 1.001
SEPB -0.044 - 0.701 1.044
Pre BCVA (logMAR) 0.205 - 0.094 1.207

VIF = variance inflation factor; M-score = metamorphopsia score; SEPB = secondary epiretinal membrane due to peripheral break; BCVA = best corrected visual acuity; logMAR = logarithm of the minimum angle of resolution.

*Variables of model selected by stepwise selection method (R2 = 0.404, p < 0.001).

J Retin 2022;7:27-34 https://doi.org/10.21561/jor.2022.7.1.27
© 2022 J Retin