eISSN 2508-3589
pISSN 2508-1926

Table. 2.

Table. 2.

Comparison of mGCIPL thickness between the Mactel and control groups as measured by Cirrus OCT

Thickness (μm) Mactel (n = 26) Control (n = 26) p-value*
Average 75.1 ± 10.2 82.2 ± 9.6 0.041
Minimum 52.2 ± 19.1 64.3 ± 19.9 0.033
Superotemporal 70.7 ± 17.7 81.8 ± 14.2 0.018
Superior 79.5 ± 13.3 82.5 ± 12.9 0.424
Superonasal 78.7 ± 10.5 82.5 ± 11.7 0.239
Inferonasal 78.3 ± 12.3 81.8 ± 8.9 0.253
Inferior 78.8 ± 13.3 82.1 ± 10.8 0.339
inferotemporal 73.1 ± 12.5 82.2 ± 13.2 0.016

Values are presented as mean ± standard deviation. mGCIPL = macular ganglion cell-inner plexiform layer; Mactel = macular telangiectasia; OCT = optical coherence tomography.

*Mann-Whitney U test.

J Retin 2022;7:49-53 https://doi.org/10.21561/jor.2022.7.1.49
© 2022 J Retin